Top 10 electrical wire direct burial
If you looking for electrical wire direct burial then you are right place. We are searching for the best electrical wire direct burial on the market and analyze these products to provide you the best choice.
1. Southwire 13055926 12/2WG UF Wire 100-Foot, Approved for Direct Burial Wiring
Feature
12/2WG UF Wire 100 Foot RollApproved for direct burial
UL Approved
Made in the USA
Uncoated copper conductors
Description
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.2. Southwire 13054226 14/2WG UF Wire 100-Foot, Approved for Direct Burial Wiring
Feature
14/2WG UF Wire 100 Foot RollApproved for direct burial
UL Approved
Made in the USA
Uncoated copper conductors
Description
Permitted for use in direct burial applications such as exposed or concealed wiring in damp, moist, wet, dry and corrosive locations as specified by the NEC. Southwire underground feeder cable can be used in applications such as general branch wiring, new wiring, and replacement wiring. Southwire's type UF is a thermoplastic non-metallic sheathed cable. Solid copper conductor. Type TW conductor insulation color coded with thermoplastic overall jacket. UF Thermoplastic insulated 60 C wet or dry locations. UFB Thermoplastic insulated with conductors rated at 90 C.3. SouthWire Company 13055955 12/2WG UF Wire 250-Foot
Feature
12/2WG UF Wire 250 Foot RollApproved for direct burial
UL Approved
Made in the USA
Uncoated copper conductors
Description
Type UF B cable is designed specifically for use as underground feeder cable for direct earth burial in branch circuits, and indoors for wet or corrosive locations. Highly resistant to acids, alkalis, corrosive fumes, chemicals, lubricants, and ground water. It is non corroding, sunlight resistant, and will not support combustion. UL listed. Shrink wrapped.4. 250' 10/2 W/G UF Cable
Feature
250'600 Volt
Copper conductors
May be used underground, including direct burial
Thermo plastic non-metallic
Description
Southwire Type UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2008 National Electrical Code. UF-B cable may be used underground, including direct burial Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90C (with ampacity limited to that for 60C conductors) as specified by the National Electrical Code UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code Voltage rating for UF-B cable is 600 volts.5. Southwire 13056722 10/2WG UF Wire 50-Foot
Feature
10/2WG UF Wire 50 Foot RollApproved for direct burial
UL Approved
Uncoated copper conductors
Description
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.6. 12/2 UF-B Wire, Underground Feeder and Direct Earth Burial Cable (150ft Cut)
Feature
#12 AWG Wire with 2 Annealed (Soft) Copper (Cu) ConductorsUsed Indoors for Wet or Corrosive Locations, Resistant to Light and Moisture
Used Outdoors for Direct Earth Burial, Resistant to Sunlight, Moisture and Fungus
Has a Heat Capacity of 90 degreesC and is rated for 600-Volts, Has an Allowable Ampacity of 20 Amps
Color of Wire May not be the Same as the Picture Shown.
Description
Applications:
UF-B is an underground feeder and branch circuit wiring cable. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90C dry / wet, its ampacity is limited to 60C according to the NEC 2008 AND NEC 2011. UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 and NEC 2011 Article 334.
Standards:
ASTM - B3 and B-8
UL Standard 83
UL Standard 493
Federal Specification A-A-59544
National Electrical Code, NFPA 70, 2011 Edition
RoHS/REACH
Construction:
Insulation: Polyvinyl Chloride (PVC) with a nylon covering. Color coded phase identification.
Jacket:Sunlight, moisture and fungus resistant gray PVC.
Specifications:
Size:12 AWG
Number of Conductors:2
PVC Insulation Thickness:0.030 inches
Ground Wire Size:12 AWG
Nylon Thickness:0.005 inches
Nominal Cable Dimensions:.463 inches x .183 inches
Weight per Foot: 0.95 lbs
Allowable Ampacity: 20 Amps
7. Southwire Underground Feeder Wire 12 Ga, 2 Conductor 20 Amp 600 V 90 Deg C 1000 ' Gray
Feature
Romex simpull building wire, Type uf-b, 12 AWG conductor, 2 conductors, Copper conductorUsed as feeder to outside post lamps, pumps and other loads
Southwire/Coleman cable
Description
Romex SIMpull building wire, type uf-b, 12 AWG conductor, 2 conductors, copper conductor, 1000 ft length, 1 strands, 20 a, 600 V, PVC insulation, nylon jacket, Gray jacket, 90 deg c, UL listed, used as Feeder to outside post lamps, pumps and other loads.8. 12/2 UF (150') Southwire "Romex"
Feature
12/2 UF (Underground Feeder - Direct Burial) CableAuthentic Southwire "Romex" Brand
3 Wires Total (3 - #12 Solid Copper Conductors)
Sunlight Resistant
150' Coil
Description
1 - 150' coil of authentic 12/2 UF "Romex" cut from a master reel, individually packaged, and shipped free to your residence or place of business. 100% Customer Satisfaction Gaurantee9. 6/3 UF (Underground Feeder - Direct Earth Burial) Cable
Feature
6/3 UF (Underground Feeder - Direct Burial) CableAuthentic Southwire "Romex" Brand
4 Wires Total (3 - #6 Stranded and 1 - #10 Solid Copper Conductors)
Sunlight Resistant
100' Coil
Description
1 - 100' coil of authentic 6/3 UF "Romex" cut from a master reel, individually packaged, and shipped free to your residence or place of business. 100% Customer Satisfaction Gaurantee. Order Carefully No Returns.10. Cerro Wire 138-1602CR-3 Type UF-B 100-Foot 2-Conductor Underground Feeder Cable
Feature
With 90 insulation, 600 Volts, Type UF-B; Cirtuf Underground Feeder CableAssembly: Two insulated 12-AWG conductors are laid parallel with one bare 12-AWG grounding conductor
Two Solid 12-AWG Conductors: Soft, uncoated copper per ASTM-B3; One Solid 12-AWG Grounding Conductor: Soft, uncoated copper per ASTM-B3
Industry Standards: UL 83 (insulated conductors), File No. E15119; UL 493 Thermoplastic-Insulated Underground Feeder Cables, File No. E26403; ASTM-B3; Federal Specification A-A-59544; NFPA70: National Electrical Code
Package Code: "C" (100' Coil); Jacket: A gray, sunlight resistant PVC (polyvinyl chloride) is applied directly over and around the two insulated and one bare ground conductors
Recent Comments